Copyright © Breeze Co.,Ltd Introduction All rights reserved. Site Map
Product Description
ET-100 settlement monitoring static level is a high-precision liquid level measuring instrument used to measure the relative settlement of foundations and various measuring points of buildings. It consists of a liquid reservoir, imported high-precision core body, special customized circuit module, protective cover and other components. It is suitable for settlement displacement measurement with small measuring range and high precision.
The static level is a high-precision liquid level measuring instrument used to measure the relative settlement of foundations and various measuring points of buildings. Application sites include measurement of uneven settlement of various measuring points in large buildings, such as hydropower plants, dams, high-rise buildings, nuclear power plants, water conservancy project projects, railways, subways, high-speed railways, comprehensive pipe corridors, etc. The ET-100 is a product specially tailored for comprehensive pipe gallery settlement monitoring.
Main features
●Measuring range: 0-500-2500mmH2O
●Accuracy 0.2mm, resolution 0.01mm
●Technology Swiss KELLER
●Wide voltage input DC9~36V
●Wide operating temperature -40~+85℃
●Lossless overvoltage 1.5 times full scale
●Baud rate adjustable from 2400~115200
●IP67 protection level
●Output RS485/MODBUS (optional)
Applications
●High-voltage wire tower monitoring
●Building (housing) settlement
●Metro foundation pit tunnel
●Monitoring and uneven settlement measurement of foundation layers, roadbeds, cuttings, bridges, buildings, subways and bridge-to-road transition sections.
●Comprehensive pipe gallery
●Large liquid storage tank
●Water conservancy project
●Angle control of various engineering machinery
●Bridges, dams, and monitoring
Performance parameters
parameter | condition | ET-100 | unit | |||
Measuring range | 50 | 100 | 200 | 1000 | mmH2O | |
Sensitivity | 0.01 | 0.01 | 0.01 | 0.01 | mmH2O | |
Temperature effect | -40~85° | ±0.3 | ±0.6 | ±0.8 | ±1 | mmH2O |
Frequency response | DC response | 100 | 100 | 100 | 100 | Hz |
resolution | 0.01 | 0.01 | 0.01 | 0.01 | mmH2O | |
Accuracy | -40~85℃ | 0.2 | 0.3 | 0.5 | 1 | mmH2O |
long term stability | -40~85℃ | <0.023 | <0.32 | <0.51 | <0.15 | mmH2O |
Power-on start time | 0.2 | 0.2 | 0.2 | 0.2 | s | |
Response time | 0.01 | 0.01 | 0.01 | 0.01 | s | |
rate | 5Hz output, 15Hz, 35Hz, 50Hz can be set (RS485 does not have this function) | |||||
output signal | RS485, MODBUS can be ordered | |||||
average working hours | ≥45000 hours/time | |||||
Lossless overvoltage | 1.5 times full scale | |||||
Insulation resistance | ≥100MΩ | |||||
waterproof level | IP67 | |||||
Cable | Standard configuration: 1.5 meter length, wear-resistant, oil-proof, wide temperature, shielded cable 4*0.2mm2 | |||||
weight | 1000g (excluding packaging box) |