You are here:

Tilt sensor T70-E

T70-E
Product Description
T70-E is a high-performance relay output single-axis dual-way tilt switch. The product has a measurement range of 0~±90° and a set of built-in relay output circuits. When the inclination angle value is greater than the preset alarm threshold, a non-inductive contact relay signal (driving current 1A) will be output, and the solenoid valve will be opened to perform corresponding hydraulic leg leveling. The alarm threshold is calibrated at the factory, and users can also set the alarm angle threshold by themselves.
The product integrates imported core units and is aimed at industry applications related to horizontal safety alarms and platform leveling monitoring. It uses a transistor output circuit to drive the solenoid valve to shut off the hydraulic system, buzzer, alarm light... to automatically warn workers of safe construction, and the product design is precise , the temperature and linearity are re-compensated, and comprehensive protection functions such as short circuit, instantaneous high voltage, polarity, and surge are integrated, making it suitable for various harsh industrial environment operations.
Main features
●Dual-axis tilt angle monitoring 
●Full range accuracy 0.1°, resolution 0.01° 
●Alarm threshold user-settable 
●Wide voltage input DC 9~36V
●Wide operating temperature -40~+85℃ 
●Measurement range 0~±90°(optional) 
●High vibration resistance >3500g 
●Industrial grade design
●IP67 protection level 
●Relay output (normally open and normally closed), and output RS232 at the same time 
●Volume (90*40*27mm) (can be customized)
Applications
●Railway gauge ruler, gauge instrument 
●Satellite solar antenna positioning 
●Tractors, deep plowing agricultural machinery 
●Mining machinery, oil logging equipment 
●Medical equipment
● Pan-tilt leveling 
● Hydraulic lifting platform 
● Based on tilt monitoring 
● Angle control of various construction machinery 
● Bridges, dams, monitoring

parameter

condition

T70-E

unit

Measuring range

±180

°

Measuring axis

X, Y axis

Alarm axis

X, Y axis

Frequency response

DC response

100

Hz

resolution

Bandwidth 5Hz

0.01

°

Accuracy

-40~85℃

0.1

°

long term stability

-40~85℃

0.1

°

Power-on start time

0.5

S

output signal

Relay (normally open and normally closed) output, RS232 and TTL optional at the same time

average working hours

≥55000 hours/time

Impact resistance

3500g, 0.5ms, 3 times/axis

Anti-vibration

10grms, 10~1000Hz

Insulation resistance

≥100MΩ

waterproof level

IP67

Cable

Standard 1.5 meter length, wear-resistant, oil-proof, wide temperature, shielded cable 8*0.3mm2

weight

150g (excluding packaging box)


×

Contact Us

captcha